Network Working Group F. Baker Request for Comments: 2206 Cisco Systems Category: Standards Track J. Krawczyk ArrowPoint Communications A. Sastry Cisco Systems September 1997
This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.
This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP-based internets. In particular, it defines objects for managing the Resource Reservation Protocol (RSVP) within the interface attributes defined in the Integrated Services Model. Thus, the Integrated Services MIB is directly relevant to and cross-referenced by this MIB. Comments should be made to the RSVP Working Group, rsvp@isi.edu.
1 The SNMPv2 Network Management Framework
1.1 Object Definitions
2 Overview
2.1 Textual Conventions
2.2 Structure of MIB
2.3 Semantics of Writing the Path and Reservation
State Databases
2.4 Intended use of Flow Notifications
2.4.1 The lostFlow Notification
2.4.2 The newFlow Notification
3 Definitions
3.1 RSVP Session Statistics Database
3.2 RSVP Session Sender Database
3.3 RSVP Reservations Requested Database
3.4 RSVP Reservation Requests Database
3.5 RSVP Interface Attributes Database
3.6 RSVP Neighbor Database
3.7 Notifications
4 Security Considerations
5 Authors' Addresses
6 Acknowledgements
7 References
The SNMPv2 Network Management Framework consists of four major components. They are:
The Framework permits new objects to be defined for the purpose of experimentation and evaluation.
Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the subset of Abstract Syntax Notation One (ASN.1) defined in the SMI. In particular, each object type is named by an OBJECT IDENTIFIER, an administratively assigned name. The object type together with an object instance serves to uniquely identify a specific instantiation of the object. For human convenience, we often use a textual string, termed the descriptor, to refer to the object type.
Several new data types are introduced as a textual convention in this MIB document. These textual conventions enhance the readability of the specification and can ease comparison with other specifications if appropriate. It should be noted that the introduction of the these textual conventions has no effect on either the syntax nor the semantics of any managed objects. The use of these is merely an artifact of the explanatory method used. Objects defined in terms of one of these methods are always encoded by means of the rules that define the primitive type. Hence, no changes to the SMI or the SNMP are necessary to accommodate these textual conventions which are adopted merely for the convenience of readers and writers in pursuit of the elusive goal of clear, concise, and unambiguous MIB documents.
The MIB is composed of the following sections:
General Objects
Session Statistics Table
Session Sender Table
Reservation Requests Received Table
Reservation Requests Forwarded Table
RSVP Interface Attributes Table
RSVP Neighbor Table
As a general rule, it is difficult in SNMP to describe arbitrarily long of complex messages; this MIB therefore seeks to describe the Path State Database and the Reservation State Database as though each flow and filter description received in an aggregate message had been received in a separate reservation message.
Thus, if a RESV message is received for session 224.1.2.3+UDP+4455 with two filter/flow spec groups describing a sender 1.2.3.4 and another sender 1.2.7.8, these two will show in the MIB as two separate rows: one for 224.1.2.3+UDP+4455 from 1.2.3.4 and the other for 224.1.2.3+UDP+4455 from 1.2.7.8.
The path and reservation state tables are writeable. Writing into the Path and Reservation State databases allows one to perform RSVP reservations without authenticating through RSVP mechanisms, but
rather through SNMP mechanisms. State created in this way by SNMP does not time out and cannot be deleted by receiving an RSVP teardown message; it can only be deleted by SNMP. Deletion is accomplished by writing 'destroy' to the associated Row Status object, and this will initiate a teardown message as if the state had timed out.
The Lost Flow notification is an asychronous event that signifies that a flow is no longer being observed.
The newFlow Notification defined in this MIB can be used to advise a network management system of the state of a flow.
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32,
NOTIFICATION-TYPE, Integer32, mib-2
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue, RowStatus,
TimeStamp, TestAndIncr, TimeInterval
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF Port, SessionNumber, SessionType, Protocol, QosService, intSrvFlowStatus, MessageSize, BitRate, BurstSize FROM INTEGRATED-SERVICES-MIB ifIndex, InterfaceIndex FROM IF-MIB;
rsvp MODULE-IDENTITY
LAST-UPDATED "9511030500Z" -- Thu Aug 28 09:03:53 PDT 1997
ORGANIZATION "IETF RSVP Working Group"
CONTACT-INFO
" Fred Baker Postal: Cisco Systems 519 Lado Drive Santa Barbara, California 93111 Tel: +1 805 681 0115 E-Mail: fred@cisco.com
John Krawczyk
Postal: ArrowPoint Communications
235 Littleton Road
Westford, Massachusetts 01886
Tel: +1 508 692 5875 E-Mail: jjk@tiac.net
Arun Sastry
Postal: Cisco Systems
210 W. Tasman Drive
San Jose, California 95134
Tel: +1 408 526 7685 E-Mail: arun@cisco.com" DESCRIPTION "The MIB module to describe the RSVP Protocol" ::= { mib-2 51 } rsvpObjects OBJECT IDENTIFIER ::= { rsvp 1 } -- tables rsvpGenObjects OBJECT IDENTIFIER ::= { rsvp 2 } -- global objects rsvpNotificationsPrefix OBJECT IDENTIFIER ::= { rsvp 3 } -- traps rsvpConformance OBJECT IDENTIFIER ::= { rsvp 4 } -- conformance RsvpEncapsulation ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This indicates the encapsulation that an RSVP Neighbor is perceived to be using." SYNTAX INTEGER { ip (1), -- IP Protocol 46 udp (2), -- UDP Encapsulation both (3) -- neighbor is using both encapsulations } RefreshInterval ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "The number of milliseconds that are expected to elapse between refreshes of path or reserva- tion state. Unrefreshed Path or reservation state is removed after a small multiple of this period."
SYNTAX INTEGER (0..'7FFFFFFF'h)
rsvpSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsvpSessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of all sessions seen by a given sys- tem." ::= { rsvpObjects 1 }
rsvpSessionEntry OBJECT-TYPE
SYNTAX RsvpSessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single session seen by a given system." INDEX { rsvpSessionNumber } ::= { rsvpSessionTable 1 } RsvpSessionEntry ::= SEQUENCE { rsvpSessionNumber SessionNumber, rsvpSessionType SessionType, rsvpSessionDestAddr OCTET STRING, rsvpSessionDestAddrLength INTEGER, rsvpSessionProtocol Protocol, rsvpSessionPort Port, rsvpSessionSenders Gauge32, rsvpSessionReceivers Gauge32, rsvpSessionRequests Gauge32 }
rsvpSessionNumber OBJECT-TYPE
SYNTAX SessionNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of this session. This is for SNMP
Indexing purposes only and has no relation to
any protocol value."
::= { rsvpSessionEntry 1 }
rsvpSessionType OBJECT-TYPE
SYNTAX SessionType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of session (IP4, IP6, IP6 with flow information, etc)." ::= { rsvpSessionEntry 2 }
rsvpSessionDestAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The destination address used by all senders in this session. This object may not be changed when the value of the RowStatus object is 'ac- tive'." ::= { rsvpSessionEntry 3 }
rsvpSessionDestAddrLength OBJECT-TYPE
SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The CIDR prefix length of the session address, which is 32 for IP4 host and multicast ad- dresses, and 128 for IP6 addresses. This ob- ject may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpSessionEntry 4 }
rsvpSessionProtocol OBJECT-TYPE
SYNTAX Protocol MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Protocol used by this session. This object may not be changed when the value of the RowStatus object is 'active'."
::= { rsvpSessionEntry 5 }
rsvpSessionPort OBJECT-TYPE
SYNTAX Port MAX-ACCESS read-only STATUS current DESCRIPTION "The UDP or TCP port number used as a destina- tion port for all senders in this session. If the IP protocol in use, specified by rsvpSen- derProtocol, is 50 (ESP) or 51 (AH), this represents a virtual destination port number. A value of zero indicates that the IP protocol in use does not have ports. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpSessionEntry 6 }
rsvpSessionSenders OBJECT-TYPE
SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of distinct senders currently known to be part of this session." ::= { rsvpSessionEntry 7 }
rsvpSessionReceivers OBJECT-TYPE
SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of reservations being requested of this system for this session." ::= { rsvpSessionEntry 8 }
rsvpSessionRequests OBJECT-TYPE
SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of reservation requests this system is sending upstream for this session." ::= { rsvpSessionEntry 9 }
rsvpBadPackets OBJECT-TYPE
SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object keeps a count of the number of bad RSVP packets received." ::= { rsvpGenObjects 1 }
rsvpSenderNewIndex OBJECT-TYPE
SYNTAX TestAndIncr MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to assign values to rsvpSenderNumber as described in 'Textual Con- ventions for SNMPv2'. The network manager reads the object, and then writes the value back in the SET that creates a new instance of rsvpSenderEntry. If the SET fails with the code 'inconsistentValue', then the process must be repeated; If the SET succeeds, then the ob- ject is incremented, and the new instance is created according to the manager's directions." ::= { rsvpGenObjects 2 }
rsvpSenderTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsvpSenderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information describing the state information displayed by senders in PATH messages." ::= { rsvpObjects 2 }
rsvpSenderEntry OBJECT-TYPE
SYNTAX RsvpSenderEntry MAX-ACCESS not-accessible STATUS current
DESCRIPTION
"Information describing the state information
displayed by a single sender's PATH message."
INDEX { rsvpSessionNumber, rsvpSenderNumber }
::= { rsvpSenderTable 1 }
SEQUENCE {
rsvpSenderNumber SessionNumber, rsvpSenderType SessionType, rsvpSenderDestAddr OCTET STRING, rsvpSenderAddr OCTET STRING, rsvpSenderDestAddrLength INTEGER, rsvpSenderAddrLength INTEGER, rsvpSenderProtocol Protocol, rsvpSenderDestPort Port, rsvpSenderPort Port, rsvpSenderFlowId INTEGER, rsvpSenderHopAddr OCTET STRING, rsvpSenderHopLih Integer32, rsvpSenderInterface InterfaceIndex, rsvpSenderTSpecRate BitRate, rsvpSenderTSpecPeakRate BitRate, rsvpSenderTSpecBurst BurstSize, rsvpSenderTSpecMinTU MessageSize, rsvpSenderTSpecMaxTU MessageSize, rsvpSenderInterval RefreshInterval, rsvpSenderRSVPHop TruthValue, rsvpSenderLastChange TimeStamp, rsvpSenderPolicy OCTET STRING, rsvpSenderAdspecBreak TruthValue, rsvpSenderAdspecHopCount INTEGER, rsvpSenderAdspecPathBw BitRate, rsvpSenderAdspecMinLatency Integer32, rsvpSenderAdspecMtu INTEGER, rsvpSenderAdspecGuaranteedSvc TruthValue, rsvpSenderAdspecGuaranteedBreak TruthValue, rsvpSenderAdspecGuaranteedCtot Integer32, rsvpSenderAdspecGuaranteedDtot Integer32, rsvpSenderAdspecGuaranteedCsum Integer32, rsvpSenderAdspecGuaranteedDsum Integer32, rsvpSenderAdspecGuaranteedHopCount INTEGER, rsvpSenderAdspecGuaranteedPathBw BitRate, rsvpSenderAdspecGuaranteedMinLatency Integer32, rsvpSenderAdspecGuaranteedMtu INTEGER, rsvpSenderAdspecCtrlLoadSvc TruthValue,
rsvpSenderAdspecCtrlLoadBreak TruthValue, rsvpSenderAdspecCtrlLoadHopCount INTEGER, rsvpSenderAdspecCtrlLoadPathBw BitRate, rsvpSenderAdspecCtrlLoadMinLatency Integer32, rsvpSenderAdspecCtrlLoadMtu INTEGER, rsvpSenderStatus RowStatus, rsvpSenderTTL INTEGER }
rsvpSenderNumber OBJECT-TYPE
SYNTAX SessionNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of this sender. This is for SNMP Indexing purposes only and has no relation to any protocol value." ::= { rsvpSenderEntry 1 }
rsvpSenderType OBJECT-TYPE
SYNTAX SessionType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of session (IP4, IP6, IP6 with flow information, etc)." ::= { rsvpSenderEntry 2 }
rsvpSenderDestAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "The destination address used by all senders in this session. This object may not be changed when the value of the RowStatus object is 'ac- tive'." ::= { rsvpSenderEntry 3 }
rsvpSenderAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-create STATUS current
DESCRIPTION
"The source address used by this sender in this
session. This object may not be changed when
the value of the RowStatus object is 'active'."
::= { rsvpSenderEntry 4 }
rsvpSenderDestAddrLength OBJECT-TYPE
SYNTAX INTEGER(0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The length of the destination address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpSenderEntry 5 }
rsvpSenderAddrLength OBJECT-TYPE
SYNTAX INTEGER(0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The length of the sender's address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpSenderEntry 6 }
rsvpSenderProtocol OBJECT-TYPE
SYNTAX Protocol MAX-ACCESS read-create STATUS current DESCRIPTION "The IP Protocol used by this session. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpSenderEntry 7 }
rsvpSenderDestPort OBJECT-TYPE
SYNTAX Port MAX-ACCESS read-create STATUS current
DESCRIPTION
"The UDP or TCP port number used as a destina-
tion port for all senders in this session. If
the IP protocol in use, specified by rsvpSen-
derProtocol, is 50 (ESP) or 51 (AH), this
represents a virtual destination port number.
A value of zero indicates that the IP protocol
in use does not have ports. This object may
not be changed when the value of the RowStatus
object is 'active'."
::= { rsvpSenderEntry 8 }
rsvpSenderPort OBJECT-TYPE
SYNTAX Port MAX-ACCESS read-create STATUS current DESCRIPTION "The UDP or TCP port number used as a source port for this sender in this session. If the IP protocol in use, specified by rsvpSenderPro- tocol is 50 (ESP) or 51 (AH), this represents a generalized port identifier (GPI). A value of zero indicates that the IP protocol in use does not have ports. This object may not be changed when the value of the RowStatus object is 'ac- tive'." ::= { rsvpSenderEntry 9 }
rsvpSenderFlowId OBJECT-TYPE
SYNTAX INTEGER (0..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "The flow ID that this sender is using, if this is an IPv6 session." ::= { rsvpSenderEntry 10 }
rsvpSenderHopAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "The address used by the previous RSVP hop (which may be the original sender)." ::= { rsvpSenderEntry 11 }
rsvpSenderHopLih OBJECT-TYPE
SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The Logical Interface Handle used by the pre- vious RSVP hop (which may be the original sender)." ::= { rsvpSenderEntry 12 }
rsvpSenderInterface OBJECT-TYPE
SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex value of the interface on which this PATH message was most recently received." ::= { rsvpSenderEntry 13 }
rsvpSenderTSpecRate OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "The Average Bit Rate of the sender's data stream. Within a transmission burst, the ar- rival rate may be as fast as rsvpSenderTSpec- PeakRate (if supported by the service model); however, averaged across two or more burst in- tervals, the rate should not exceed rsvpSen- derTSpecRate.
Note that this is a prediction, often based on
the general capability of a type of codec or
particular encoding; the measured average rate
may be significantly lower."
::= { rsvpSenderEntry 14 }
rsvpSenderTSpecPeakRate OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION
"The Peak Bit Rate of the sender's data stream.
Traffic arrival is not expected to exceed this
rate at any time, apart from the effects of
jitter in the network. If not specified in the
TSpec, this returns zero or noSuchValue."
::= { rsvpSenderEntry 15 }
rsvpSenderTSpecBurst OBJECT-TYPE
SYNTAX BurstSize UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION "The size of the largest burst expected from the sender at a time." ::= { rsvpSenderEntry 16 }
rsvpSenderTSpecMinTU OBJECT-TYPE
SYNTAX MessageSize MAX-ACCESS read-create STATUS current DESCRIPTION "The minimum message size for this flow. The policing algorithm will treat smaller messages as though they are this size." ::= { rsvpSenderEntry 17 }
rsvpSenderTSpecMaxTU OBJECT-TYPE
SYNTAX MessageSize MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum message size for this flow. The admission algorithm will reject TSpecs whose Maximum Transmission Unit, plus the interface headers, exceed the interface MTU." ::= { rsvpSenderEntry 18 }
rsvpSenderInterval OBJECT-TYPE
SYNTAX RefreshInterval MAX-ACCESS read-create STATUS current DESCRIPTION "The interval between refresh messages as ad-
vertised by the Previous Hop."
::= { rsvpSenderEntry 19 }
rsvpSenderRSVPHop OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, the node believes that the previous IP hop is an RSVP hop. If FALSE, the node be- lieves that the previous IP hop may not be an RSVP hop." ::= { rsvpSenderEntry 20 }
rsvpSenderLastChange OBJECT-TYPE
SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The time of the last change in this PATH mes- sage; This is either the first time it was re- ceived or the time of the most recent change in parameters." ::= { rsvpSenderEntry 21 }
rsvpSenderPolicy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..65536)) MAX-ACCESS read-create STATUS current DESCRIPTION "The contents of the policy object, displayed as an uninterpreted string of octets, including the object header. In the absence of such an object, this should be of zero length." ::= { rsvpSenderEntry 22 }
rsvpSenderAdspecBreak OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The global break bit general characterization parameter from the ADSPEC. If TRUE, at least one non-IS hop was detected in the path. If
FALSE, no non-IS hops were detected."
::= { rsvpSenderEntry 23 }
rsvpSenderAdspecHopCount OBJECT-TYPE
SYNTAX INTEGER (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The hop count general characterization parame- ter from the ADSPEC. A return of zero or noSuchValue indicates one of the following con- ditions:
the invalid bit was set
the parameter was not present"
::= { rsvpSenderEntry 24 }
rsvpSenderAdspecPathBw OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "The path bandwidth estimate general character- ization parameter from the ADSPEC. A return of zero or noSuchValue indicates one of the fol- lowing conditions:
the invalid bit was set
the parameter was not present"
::= { rsvpSenderEntry 25 }
rsvpSenderAdspecMinLatency OBJECT-TYPE
SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The minimum path latency general characteriza- tion parameter from the ADSPEC. A return of zero or noSuchValue indicates one of the fol- lowing conditions:
the invalid bit was set
the parameter was not present"
::= { rsvpSenderEntry 26 }
rsvpSenderAdspecMtu OBJECT-TYPE
SYNTAX INTEGER (0..65535) UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION "The composed Maximum Transmission Unit general characterization parameter from the ADSPEC. A return of zero or noSuchValue indicates one of the following conditions:
the invalid bit was set
the parameter was not present"
::= { rsvpSenderEntry 27 }
rsvpSenderAdspecGuaranteedSvc OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, the ADSPEC contains a Guaranteed Ser- vice fragment. If FALSE, the ADSPEC does not contain a Guaranteed Service fragment." ::= { rsvpSenderEntry 28 }
rsvpSenderAdspecGuaranteedBreak OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, the Guaranteed Service fragment has its 'break' bit set, indicating that one or more nodes along the path do not support the guaranteed service. If FALSE, and rsvpSen- derAdspecGuaranteedSvc is TRUE, the 'break' bit is not set.
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns FALSE or noSuchValue."
::= { rsvpSenderEntry 29 }
rsvpSenderAdspecGuaranteedCtot OBJECT-TYPE
SYNTAX Integer32 UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION
"If rsvpSenderAdspecGuaranteedSvc is TRUE, this
is the end-to-end composed value for the guaranteed service 'C' parameter. A return of zero or noSuchValue indicates one of the fol- lowing conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 30 }
rsvpSenderAdspecGuaranteedDtot OBJECT-TYPE
SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecGuaranteedSvc is TRUE, this is the end-to-end composed value for the guaranteed service 'D' parameter. A return of zero or noSuchValue indicates one of the fol- lowing conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 31 }
rsvpSenderAdspecGuaranteedCsum OBJECT-TYPE
SYNTAX Integer32 UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecGuaranteedSvc is TRUE, this is the composed value for the guaranteed ser-
vice 'C' parameter since the last reshaping
point. A return of zero or noSuchValue indi-
cates one of the following conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 32 }
rsvpSenderAdspecGuaranteedDsum OBJECT-TYPE
SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecGuaranteedSvc is TRUE, this is the composed value for the guaranteed ser- vice 'D' parameter since the last reshaping point. A return of zero or noSuchValue indi- cates one of the following conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 33 }
rsvpSenderAdspecGuaranteedHopCount OBJECT-TYPE
SYNTAX INTEGER (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION
"If rsvpSenderAdspecGuaranteedSvc is TRUE, this
is the service-specific override of the hop
count general characterization parameter from
the ADSPEC. A return of zero or noSuchValue
indicates one of the following conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 34 }
rsvpSenderAdspecGuaranteedPathBw OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecGuaranteedSvc is TRUE, this is the service-specific override of the path bandwidth estimate general characterization parameter from the ADSPEC. A return of zero or noSuchValue indicates one of the following con- ditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 35 }
rsvpSenderAdspecGuaranteedMinLatency OBJECT-TYPE
SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecGuaranteedSvc is TRUE, this is the service-specific override of the minimum path latency general characterization parameter from the ADSPEC. A return of zero or noSuch- Value indicates one of the following condi- tions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 36 }
rsvpSenderAdspecGuaranteedMtu OBJECT-TYPE
SYNTAX INTEGER (0..65535)
UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecGuaranteedSvc is TRUE, this is the service-specific override of the com- posed Maximum Transmission Unit general charac- terization parameter from the ADSPEC. A return of zero or noSuchValue indicates one of the following conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecGuaranteedSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 37 }
rsvpSenderAdspecCtrlLoadSvc OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, the ADSPEC contains a Controlled Load Service fragment. If FALSE, the ADSPEC does not contain a Controlled Load Service frag- ment." ::= { rsvpSenderEntry 38 }
rsvpSenderAdspecCtrlLoadBreak OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, the Controlled Load Service fragment has its 'break' bit set, indicating that one or more nodes along the path do not support the controlled load service. If FALSE, and rsvpSenderAdspecCtrlLoadSvc is TRUE, the 'break' bit is not set.
If rsvpSenderAdspecCtrlLoadSvc is FALSE, this
returns FALSE or noSuchValue."
::= { rsvpSenderEntry 39 }
rsvpSenderAdspecCtrlLoadHopCount OBJECT-TYPE
SYNTAX INTEGER (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION
"If rsvpSenderAdspecCtrlLoadSvc is TRUE, this
is the service-specific override of the hop
count general characterization parameter from
the ADSPEC. A return of zero or noSuchValue
indicates one of the following conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecCtrlLoadSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 40 }
rsvpSenderAdspecCtrlLoadPathBw OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecCtrlLoadSvc is TRUE, this is the service-specific override of the path bandwidth estimate general characterization parameter from the ADSPEC. A return of zero or noSuchValue indicates one of the following con- ditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecCtrlLoadSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 41 }
rsvpSenderAdspecCtrlLoadMinLatency OBJECT-TYPE
SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecCtrlLoadSvc is TRUE, this
is the service-specific override of the minimum
path latency general characterization parameter
from the ADSPEC. A return of zero or noSuch-
Value indicates one of the following condi-
tions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecCtrlLoadSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 42 }
rsvpSenderAdspecCtrlLoadMtu OBJECT-TYPE
SYNTAX INTEGER (0..65535) UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION "If rsvpSenderAdspecCtrlLoadSvc is TRUE, this is the service-specific override of the com- posed Maximum Transmission Unit general charac- terization parameter from the ADSPEC. A return of zero or noSuchValue indicates one of the following conditions:
the invalid bit was set
the parameter was not present
If rsvpSenderAdspecCtrlLoadSvc is FALSE, this
returns zero or noSuchValue."
::= { rsvpSenderEntry 43 }
rsvpSenderStatus OBJECT-TYPE
SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "'active' for all active PATH messages. This object may be used to install static PATH in- formation or delete PATH information." ::= { rsvpSenderEntry 44 }
rsvpSenderTTL OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current DESCRIPTION "The TTL value in the RSVP header that was last received." ::= { rsvpSenderEntry 45 }
rsvpSenderOutInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsvpSenderOutInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of outgoing interfaces that PATH messages use. The ifIndex is the ifIndex value of the egress interface." ::= { rsvpObjects 3 }
rsvpSenderOutInterfaceEntry OBJECT-TYPE
SYNTAX RsvpSenderOutInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of outgoing interfaces that a particular PATH message has." INDEX { rsvpSessionNumber, rsvpSenderNumber, ifIndex } ::= { rsvpSenderOutInterfaceTable 1 }
rsvpSenderOutInterfaceStatus RowStatus }
rsvpSenderOutInterfaceStatus OBJECT-TYPE
SYNTAX RowStatus MAX-ACCESS read-only STATUS current DESCRIPTION "'active' for all active PATH messages." ::= { rsvpSenderOutInterfaceEntry 1 }
rsvpResvNewIndex OBJECT-TYPE
SYNTAX TestAndIncr MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to assign values to rsvpResvNumber as described in 'Textual Conven- tions for SNMPv2'. The network manager reads the object, and then writes the value back in the SET that creates a new instance of rsvpResvEntry. If the SET fails with the code 'inconsistentValue', then the process must be repeated; If the SET succeeds, then the object is incremented, and the new instance is created according to the manager's directions." ::= { rsvpGenObjects 3 }
rsvpResvTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsvpResvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information describing the state information displayed by receivers in RESV messages." ::= { rsvpObjects 4 }
rsvpResvEntry OBJECT-TYPE
SYNTAX RsvpResvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information describing the state information displayed by a single receiver's RESV message concerning a single sender." INDEX { rsvpSessionNumber, rsvpResvNumber } ::= { rsvpResvTable 1 } RsvpResvEntry ::= SEQUENCE { rsvpResvNumber SessionNumber, rsvpResvType SessionType, rsvpResvDestAddr OCTET STRING, rsvpResvSenderAddr OCTET STRING, rsvpResvDestAddrLength INTEGER,
rsvpResvSenderAddrLength INTEGER, rsvpResvProtocol Protocol, rsvpResvDestPort Port, rsvpResvPort Port, rsvpResvHopAddr OCTET STRING, rsvpResvHopLih Integer32, rsvpResvInterface InterfaceIndex, rsvpResvService QosService, rsvpResvTSpecRate BitRate, rsvpResvTSpecPeakRate BitRate, rsvpResvTSpecBurst BurstSize, rsvpResvTSpecMinTU MessageSize, rsvpResvTSpecMaxTU MessageSize, rsvpResvRSpecRate BitRate, rsvpResvRSpecSlack Integer32, rsvpResvInterval RefreshInterval, rsvpResvScope OCTET STRING, rsvpResvShared TruthValue, rsvpResvExplicit TruthValue, rsvpResvRSVPHop TruthValue, rsvpResvLastChange TimeStamp, rsvpResvPolicy OCTET STRING, rsvpResvStatus RowStatus, rsvpResvTTL INTEGER, rsvpResvFlowId INTEGER }
rsvpResvNumber OBJECT-TYPE
SYNTAX SessionNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of this reservation request. This is for SNMP Indexing purposes only and has no relation to any protocol value." ::= { rsvpResvEntry 1 }
rsvpResvType OBJECT-TYPE
SYNTAX SessionType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of session (IP4, IP6, IP6 with flow information, etc)." ::= { rsvpResvEntry 2 }
rsvpResvDestAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "The destination address used by all senders in this session. This object may not be changed when the value of the RowStatus object is 'ac- tive'." ::= { rsvpResvEntry 3 }
rsvpResvSenderAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "The source address of the sender selected by this reservation. The value of all zeroes in- dicates 'all senders'. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvEntry 4 }
rsvpResvDestAddrLength OBJECT-TYPE
SYNTAX INTEGER(0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The length of the destination address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvEntry 5 }
rsvpResvSenderAddrLength OBJECT-TYPE
SYNTAX INTEGER(0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The length of the sender's address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be changed when the value of the RowStatus object is 'active'."
::= { rsvpResvEntry 6 }
rsvpResvProtocol OBJECT-TYPE
SYNTAX Protocol MAX-ACCESS read-create STATUS current DESCRIPTION "The IP Protocol used by this session. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvEntry 7 }
rsvpResvDestPort OBJECT-TYPE
SYNTAX Port MAX-ACCESS read-create STATUS current DESCRIPTION "The UDP or TCP port number used as a destina- tion port for all senders in this session. If the IP protocol in use, specified by rsvpResvProtocol, is 50 (ESP) or 51 (AH), this represents a virtual destination port number. A value of zero indicates that the IP protocol in use does not have ports. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvEntry 8 }
rsvpResvPort OBJECT-TYPE
SYNTAX Port MAX-ACCESS read-create STATUS current DESCRIPTION "The UDP or TCP port number used as a source port for this sender in this session. If the IP protocol in use, specified by rsvpResvProto- col is 50 (ESP) or 51 (AH), this represents a generalized port identifier (GPI). A value of zero indicates that the IP protocol in use does not have ports. This object may not be changed when the value of the RowStatus object is 'ac- tive'." ::= { rsvpResvEntry 9 }
rsvpResvHopAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "The address used by the next RSVP hop (which may be the ultimate receiver)." ::= { rsvpResvEntry 10 }
rsvpResvHopLih OBJECT-TYPE
SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The Logical Interface Handle received from the previous RSVP hop (which may be the ultimate receiver)." ::= { rsvpResvEntry 11 }
rsvpResvInterface OBJECT-TYPE
SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex value of the interface on which this RESV message was most recently received." ::= { rsvpResvEntry 12 }
rsvpResvService OBJECT-TYPE
SYNTAX QosService MAX-ACCESS read-create STATUS current DESCRIPTION "The QoS Service classification requested by the receiver." ::= { rsvpResvEntry 13 }
rsvpResvTSpecRate OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "The Average Bit Rate of the sender's data
stream. Within a transmission burst, the ar-
rival rate may be as fast as rsvpResvTSpec-
PeakRate (if supported by the service model);
however, averaged across two or more burst in-
tervals, the rate should not exceed rsvpResvTSpecRate.
Note that this is a prediction, often based on
the general capability of a type of codec or
particular encoding; the measured average rate
may be significantly lower."
::= { rsvpResvEntry 14 }
rsvpResvTSpecPeakRate OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "The Peak Bit Rate of the sender's data stream. Traffic arrival is not expected to exceed this rate at any time, apart from the effects of jitter in the network. If not specified in the TSpec, this returns zero or noSuchValue." ::= { rsvpResvEntry 15 }
rsvpResvTSpecBurst OBJECT-TYPE
SYNTAX BurstSize UNITS "bytes" MAX-ACCESS read-create STATUS current DESCRIPTION "The size of the largest burst expected from the sender at a time.
If this is less than the sender's advertised
burst size, the receiver is asking the network
to provide flow pacing beyond what would be
provided under normal circumstances. Such pac-
ing is at the network's option."
::= { rsvpResvEntry 16 }
rsvpResvTSpecMinTU OBJECT-TYPE
SYNTAX MessageSize MAX-ACCESS read-create
STATUS current DESCRIPTION "The minimum message size for this flow. The policing algorithm will treat smaller messages as though they are this size." ::= { rsvpResvEntry 17 }
rsvpResvTSpecMaxTU OBJECT-TYPE
SYNTAX MessageSize MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum message size for this flow. The admission algorithm will reject TSpecs whose Maximum Transmission Unit, plus the interface headers, exceed the interface MTU." ::= { rsvpResvEntry 18 }
rsvpResvRSpecRate OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "If the requested service is Guaranteed, as specified by rsvpResvService, this is the clearing rate that is being requested. Other- wise, it is zero, or the agent may return noSuchValue." ::= { rsvpResvEntry 19 }
rsvpResvRSpecSlack OBJECT-TYPE
SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "If the requested service is Guaranteed, as specified by rsvpResvService, this is the delay slack. Otherwise, it is zero, or the agent may return noSuchValue." ::= { rsvpResvEntry 20 }
rsvpResvInterval OBJECT-TYPE
SYNTAX RefreshInterval MAX-ACCESS read-create STATUS current DESCRIPTION "The interval between refresh messages as ad- vertised by the Next Hop." ::= { rsvpResvEntry 21 }
rsvpResvScope OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65536)) MAX-ACCESS read-create STATUS current DESCRIPTION
"The contents of the scope object, displayed as
an uninterpreted string of octets, including
the object header. In the absence of such an
object, this should be of zero length.
If the length is non-zero, this contains a
series of IP4 or IP6 addresses."
::= { rsvpResvEntry 22 }
rsvpResvShared OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, a reservation shared among senders is requested. If FALSE, a reservation specific to this sender is requested." ::= { rsvpResvEntry 23 }
rsvpResvExplicit OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, individual senders are listed using Filter Specifications. If FALSE, all senders are implicitly selected. The Scope Object will contain a list of senders that need to receive this reservation request for the purpose of routing the RESV message." ::= { rsvpResvEntry 24 }
rsvpResvRSVPHop OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, the node believes that the previous IP hop is an RSVP hop. If FALSE, the node be- lieves that the previous IP hop may not be an RSVP hop." ::= { rsvpResvEntry 25 }
rsvpResvLastChange OBJECT-TYPE
SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The time of the last change in this reserva- tion request; This is either the first time it was received or the time of the most recent change in parameters." ::= { rsvpResvEntry 26 }
rsvpResvPolicy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65536)) MAX-ACCESS read-create STATUS current DESCRIPTION "The contents of the policy object, displayed as an uninterpreted string of octets, including the object header. In the absence of such an object, this should be of zero length." ::= { rsvpResvEntry 27 }
rsvpResvStatus OBJECT-TYPE
SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "'active' for all active RESV messages. This object may be used to install static RESV in- formation or delete RESV information." ::= { rsvpResvEntry 28 }
rsvpResvTTL OBJECT-TYPE
SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The TTL value in the RSVP header that was last received." ::= { rsvpResvEntry 29 }
rsvpResvFlowId OBJECT-TYPE
SYNTAX INTEGER (0..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "The flow ID that this receiver is using, if this is an IPv6 session." ::= { rsvpResvEntry 30 }
rsvpResvFwdNewIndex OBJECT-TYPE
SYNTAX TestAndIncr MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to assign values to rsvpResvFwdNumber as described in 'Textual Con- ventions for SNMPv2'. The network manager reads the object, and then writes the value back in the SET that creates a new instance of rsvpResvFwdEntry. If the SET fails with the code 'inconsistentValue', then the process must be repeated; If the SET succeeds, then the ob- ject is incremented, and the new instance is created according to the manager's directions." ::= { rsvpGenObjects 4 }
rsvpResvFwdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsvpResvFwdEntry MAX-ACCESS not-accessible STATUS current
DESCRIPTION
"Information describing the state information
displayed upstream in RESV messages."
::= { rsvpObjects 5 }
rsvpResvFwdEntry OBJECT-TYPE
SYNTAX RsvpResvFwdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information describing the state information displayed upstream in an RESV message concern- ing a single sender." INDEX { rsvpSessionNumber, rsvpResvFwdNumber } ::= { rsvpResvFwdTable 1 } RsvpResvFwdEntry ::= SEQUENCE { rsvpResvFwdNumber SessionNumber, rsvpResvFwdType SessionType, rsvpResvFwdDestAddr OCTET STRING, rsvpResvFwdSenderAddr OCTET STRING, rsvpResvFwdDestAddrLength INTEGER, rsvpResvFwdSenderAddrLength INTEGER, rsvpResvFwdProtocol Protocol, rsvpResvFwdDestPort Port, rsvpResvFwdPort Port, rsvpResvFwdHopAddr OCTET STRING, rsvpResvFwdHopLih Integer32, rsvpResvFwdInterface InterfaceIndex, rsvpResvFwdService QosService, rsvpResvFwdTSpecRate BitRate, rsvpResvFwdTSpecPeakRate BitRate, rsvpResvFwdTSpecBurst BurstSize, rsvpResvFwdTSpecMinTU MessageSize, rsvpResvFwdTSpecMaxTU MessageSize, rsvpResvFwdRSpecRate BitRate, rsvpResvFwdRSpecSlack Integer32, rsvpResvFwdInterval RefreshInterval, rsvpResvFwdScope OCTET STRING, rsvpResvFwdShared TruthValue, rsvpResvFwdExplicit TruthValue, rsvpResvFwdRSVPHop TruthValue, rsvpResvFwdLastChange TimeStamp, rsvpResvFwdPolicy OCTET STRING, rsvpResvFwdStatus RowStatus,
rsvpResvFwdTTL INTEGER, rsvpResvFwdFlowId INTEGER }
rsvpResvFwdNumber OBJECT-TYPE
SYNTAX SessionNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of this reservation request. This is for SNMP Indexing purposes only and has no relation to any protocol value." ::= { rsvpResvFwdEntry 1 }
rsvpResvFwdType OBJECT-TYPE
SYNTAX SessionType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of session (IP4, IP6, IP6 with flow information, etc)." ::= { rsvpResvFwdEntry 2 }
rsvpResvFwdDestAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The destination address used by all senders in this session. This object may not be changed when the value of the RowStatus object is 'ac- tive'." ::= { rsvpResvFwdEntry 3 }
rsvpResvFwdSenderAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The source address of the sender selected by this reservation. The value of all zeroes in- dicates 'all senders'. This object may not be changed when the value of the RowStatus object is 'active'."
::= { rsvpResvFwdEntry 4 }
rsvpResvFwdDestAddrLength OBJECT-TYPE
SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the destination address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvFwdEntry 5 }
rsvpResvFwdSenderAddrLength OBJECT-TYPE
SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the sender's address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvFwdEntry 6 }
rsvpResvFwdProtocol OBJECT-TYPE
SYNTAX Protocol MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Protocol used by a session. for secure sessions, this indicates IP Security. This ob- ject may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvFwdEntry 7 }
rsvpResvFwdDestPort OBJECT-TYPE
SYNTAX Port MAX-ACCESS read-only STATUS current DESCRIPTION "The UDP or TCP port number used as a destina- tion port for all senders in this session. If
the IP protocol in use, specified by rsvpResvFwdProtocol, is 50 (ESP) or 51 (AH), this represents a virtual destination port number. A value of zero indicates that the IP protocol in use does not have ports. This ob- ject may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvFwdEntry 8 }
rsvpResvFwdPort OBJECT-TYPE
SYNTAX Port MAX-ACCESS read-only STATUS current DESCRIPTION "The UDP or TCP port number used as a source port for this sender in this session. If the IP protocol in use, specified by rsvpResvFwdProtocol is 50 (ESP) or 51 (AH), this represents a generalized port identifier (GPI). A value of zero indicates that the IP protocol in use does not have ports. This ob- ject may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpResvFwdEntry 9 }
rsvpResvFwdHopAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The address of the (previous) RSVP that will receive this message." ::= { rsvpResvFwdEntry 10 }
rsvpResvFwdHopLih OBJECT-TYPE
SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Logical Interface Handle sent to the (pre- vious) RSVP that will receive this message." ::= { rsvpResvFwdEntry 11 }
rsvpResvFwdInterface OBJECT-TYPE
SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value of the interface on which this RESV message was most recently sent." ::= { rsvpResvFwdEntry 12 }
rsvpResvFwdService OBJECT-TYPE
SYNTAX QosService MAX-ACCESS read-only STATUS current DESCRIPTION "The QoS Service classification requested." ::= { rsvpResvFwdEntry 13 }
rsvpResvFwdTSpecRate OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-only STATUS current DESCRIPTION "The Average Bit Rate of the sender's data stream. Within a transmission burst, the ar- rival rate may be as fast as rsvpResvFwdTSpec- PeakRate (if supported by the service model); however, averaged across two or more burst in- tervals, the rate should not exceed rsvpResvFwdTSpecRate.
Note that this is a prediction, often based on
the general capability of a type of codec or
particular encoding; the measured average rate
may be significantly lower."
::= { rsvpResvFwdEntry 14 }
rsvpResvFwdTSpecPeakRate OBJECT-TYPE
SYNTAX BitRate UNITS "bits per second" MAX-ACCESS read-only STATUS current DESCRIPTION "The Peak Bit Rate of the sender's data stream Traffic arrival is not expected to exceed this rate at any time, apart from the effects of
jitter in the network. If not specified in the
TSpec, this returns zero or noSuchValue."
::= { rsvpResvFwdEntry 15 }
rsvpResvFwdTSpecBurst OBJECT-TYPE
SYNTAX BurstSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The size of the largest burst expected from the sender at a time.
If this is less than the sender's advertised
burst size, the receiver is asking the network
to provide flow pacing beyond what would be
provided under normal circumstances. Such pac-
ing is at the network's option."
::= { rsvpResvFwdEntry 16 }
rsvpResvFwdTSpecMinTU OBJECT-TYPE
SYNTAX MessageSize MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum message size for this flow. The policing algorithm will treat smaller messages as though they are this size." ::= { rsvpResvFwdEntry 17 }
rsvpResvFwdTSpecMaxTU OBJECT-TYPE
SYNTAX MessageSize MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum message size for this flow. The admission algorithm will reject TSpecs whose Maximum Transmission Unit, plus the interface headers, exceed the interface MTU." ::= { rsvpResvFwdEntry 18 }
rsvpResvFwdRSpecRate OBJECT-TYPE
SYNTAX BitRate UNITS "bytes per second"
MAX-ACCESS read-only
STATUS current DESCRIPTION "If the requested service is Guaranteed, as specified by rsvpResvService, this is the clearing rate that is being requested. Other- wise, it is zero, or the agent may return noSuchValue." ::= { rsvpResvFwdEntry 19 }
rsvpResvFwdRSpecSlack OBJECT-TYPE
SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "If the requested service is Guaranteed, as specified by rsvpResvService, this is the delay slack. Otherwise, it is zero, or the agent may return noSuchValue." ::= { rsvpResvFwdEntry 20 }
rsvpResvFwdInterval OBJECT-TYPE
SYNTAX RefreshInterval MAX-ACCESS read-only STATUS current DESCRIPTION "The interval between refresh messages adver- tised to the Previous Hop." ::= { rsvpResvFwdEntry 21 }
rsvpResvFwdScope OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65536)) MAX-ACCESS read-only STATUS current DESCRIPTION "The contents of the scope object, displayed as an uninterpreted string of octets, including the object header. In the absence of such an object, this should be of zero length." ::= { rsvpResvFwdEntry 22 }
rsvpResvFwdShared OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current DESCRIPTION "If TRUE, a reservation shared among senders is requested. If FALSE, a reservation specific to this sender is requested." ::= { rsvpResvFwdEntry 23 }
rsvpResvFwdExplicit OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If TRUE, individual senders are listed using Filter Specifications. If FALSE, all senders are implicitly selected. The Scope Object will contain a list of senders that need to receive this reservation request for the purpose of routing the RESV message." ::= { rsvpResvFwdEntry 24 }
rsvpResvFwdRSVPHop OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If TRUE, the node believes that the next IP hop is an RSVP hop. If FALSE, the node be- lieves that the next IP hop may not be an RSVP hop." ::= { rsvpResvFwdEntry 25 }
rsvpResvFwdLastChange OBJECT-TYPE
SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The time of the last change in this request; This is either the first time it was sent or the time of the most recent change in parame- ters." ::= { rsvpResvFwdEntry 26 }
rsvpResvFwdPolicy OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65536)) MAX-ACCESS read-only STATUS current DESCRIPTION "The contents of the policy object, displayed as an uninterpreted string of octets, including the object header. In the absence of such an object, this should be of zero length." ::= { rsvpResvFwdEntry 27 }
rsvpResvFwdStatus OBJECT-TYPE
SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "'active' for all active RESV messages. This object may be used to delete RESV information." ::= { rsvpResvFwdEntry 28 }
rsvpResvFwdTTL OBJECT-TYPE
SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The TTL value in the RSVP header that was last received." ::= { rsvpResvFwdEntry 29 }
rsvpResvFwdFlowId OBJECT-TYPE
SYNTAX INTEGER (0..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "The flow ID that this receiver is using, if this is an IPv6 session." ::= { rsvpResvFwdEntry 30 }
rsvpIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsvpIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RSVP-specific attributes of the system's interfaces." ::= { rsvpObjects 6 }
rsvpIfEntry OBJECT-TYPE
SYNTAX RsvpIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RSVP-specific attributes of the a given interface." INDEX { ifIndex } ::= { rsvpIfTable 1 }
rsvpIfUdpNbrs Gauge32, rsvpIfIpNbrs Gauge32, rsvpIfNbrs Gauge32, rsvpIfEnabled TruthValue, rsvpIfUdpRequired TruthValue, rsvpIfRefreshBlockadeMultiple INTEGER, rsvpIfRefreshMultiple INTEGER, rsvpIfTTL INTEGER, rsvpIfRefreshInterval TimeInterval, rsvpIfRouteDelay TimeInterval, rsvpIfStatus RowStatus }
rsvpIfUdpNbrs OBJECT-TYPE
SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of neighbors perceived to be using only the RSVP UDP Encapsulation." ::= { rsvpIfEntry 1 }
rsvpIfIpNbrs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current DESCRIPTION "The number of neighbors perceived to be using only the RSVP IP Encapsulation." ::= { rsvpIfEntry 2 }
rsvpIfNbrs OBJECT-TYPE
SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of neighbors currently perceived; this will exceed rsvpIfIpNbrs + rsvpIfUdpNbrs by the number of neighbors using both encapsu- lations." ::= { rsvpIfEntry 3 }
rsvpIfRefreshBlockadeMultiple OBJECT-TYPE
SYNTAX INTEGER (1..65536) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of the RSVP value 'Kb', Which is the minimum number of refresh intervals that blockade state will last once entered." DEFVAL { 4 } ::= { rsvpIfEntry 4 }
rsvpIfRefreshMultiple OBJECT-TYPE
SYNTAX INTEGER (1..65536) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of the RSVP value 'K', which is the number of refresh intervals which must elapse (minimum) before a PATH or RESV message which is not being refreshed will be aged out." DEFVAL { 3 } ::= { rsvpIfEntry 5 }
rsvpIfTTL OBJECT-TYPE
SYNTAX INTEGER (0..255) MAX-ACCESS read-create
STATUS current DESCRIPTION "The value of SEND_TTL used on this interface for messages this node originates. If set to zero, the node determines the TTL via other means." DEFVAL { 0 } -- which is to say, no override ::= { rsvpIfEntry 6 }
rsvpIfRefreshInterval OBJECT-TYPE
SYNTAX TimeInterval UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The value of the RSVP value 'R', which is the minimum period between refresh transmissions of a given PATH or RESV message on an interface." DEFVAL { 3000 } -- 30 seconds ::= { rsvpIfEntry 7 }
rsvpIfRouteDelay OBJECT-TYPE
SYNTAX TimeInterval UNITS "hundredths of a second" MAX-ACCESS read-create STATUS current DESCRIPTION "The approximate period from the time a route is changed to the time a resulting message ap- pears on the interface." DEFVAL { 200 } -- 2 seconds ::= { rsvpIfEntry 8 }
rsvpIfEnabled OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, RSVP is enabled on this Interface. If FALSE, RSVP is not enabled on this inter- face." ::= { rsvpIfEntry 9 }
rsvpIfUdpRequired OBJECT-TYPE
SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If TRUE, manual configuration forces the use of UDP encapsulation on the interface. If FALSE, UDP encapsulation is only used if rsvpI- fUdpNbrs is not zero." ::= { rsvpIfEntry 10 }
rsvpIfStatus OBJECT-TYPE
SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "'active' on interfaces that are configured for RSVP." ::= { rsvpIfEntry 11 }
rsvpNbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsvpNbrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information describing the Neighbors of an RSVP system." ::= { rsvpObjects 7 }
rsvpNbrEntry OBJECT-TYPE
SYNTAX RsvpNbrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information describing a single RSVP Neigh- bor." INDEX { ifIndex, rsvpNbrAddress } ::= { rsvpNbrTable 1 }
rsvpNbrAddress OCTET STRING, rsvpNbrProtocol RsvpEncapsulation, rsvpNbrStatus RowStatus }
rsvpNbrAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..16)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP4 or IP6 Address used by this neighbor. This object may not be changed when the value of the RowStatus object is 'active'." ::= { rsvpNbrEntry 1 }
rsvpNbrProtocol OBJECT-TYPE
SYNTAX RsvpEncapsulation MAX-ACCESS read-create STATUS current DESCRIPTION "The encapsulation being used by this neigh- bor." ::= { rsvpNbrEntry 2 }
rsvpNbrStatus OBJECT-TYPE
SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "'active' for all neighbors. This object may be used to configure neighbors. In the pres- ence of configured neighbors, the implementa- tion may (but is not required to) limit the set of valid neighbors to those configured." ::= { rsvpNbrEntry 3 }
rsvpNotifications OBJECT IDENTIFIER
::= { rsvpNotificationsPrefix 0 }
newFlow NOTIFICATION-TYPE
OBJECTS {
intSrvFlowStatus, rsvpSessionDestAddr,
rsvpResvFwdStatus, rsvpResvStatus, rsvpSenderStatus
}
STATUS current
DESCRIPTION
"The newFlow trap indicates that the originat-
ing system has installed a new flow in its
classifier, or (when reservation authorization
is in view) is prepared to install such a flow
in the classifier and is requesting authoriza-
tion. The objects included with the Notifica-
tion may be used to read further information
using the Integrated Services and RSVP MIBs.
Authorization or non-authorization may be enacted by a write to the variable intSrvFlowS- tatus." ::= { rsvpNotifications 1 }
lostFlow NOTIFICATION-TYPE
OBJECTS {
intSrvFlowStatus, rsvpSessionDestAddr,
rsvpResvFwdStatus, rsvpResvStatus, rsvpSenderStatus
}
STATUS current
DESCRIPTION
"The lostFlow trap indicates that the originat-
ing system has removed a flow from its classif-
ier."
::= { rsvpNotifications 2 }
rsvpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement. Note that the im-
plementation of this module requires implemen-
tation of the Integrated Services MIB as well."
MODULE -- this module
MANDATORY-GROUPS {
rsvpSessionGroup, rsvpSenderGroup, rsvpResvGroup,
rsvpIfGroup, rsvpNbrGroup
}
GROUP rsvpResvFwdGroup
DESCRIPTION
"The Reservation Requests table is appropriate
in implementations that store upstream reserva-
tion messages, but not appropriate in implemen-
tations which calculate them on each transmis-
sion."
GROUP rsvpNotificationGroup
DESCRIPTION
"The notifications in this module may be used to
advise a network management station of changes in
flow status, and are required when this use is in
view."
OBJECT rsvpSessionRequests MIN-ACCESS not-accessible DESCRIPTION "This object is optional." OBJECT rsvpSenderType MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderDestAddr MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderAddr MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderDestAddrLength MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be
read-only."
OBJECT rsvpSenderAddrLength MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderProtocol MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderDestPort MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderPort MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderHopAddr MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderHopLih MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderInterface MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderTSpecRate MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be
read-only."
OBJECT rsvpSenderTSpecPeakRate MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderTSpecBurst MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderTSpecMinTU MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderTSpecMaxTU MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderInterval MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderRSVPHop MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderPolicy MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderAdspecBreak MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be
read-only."
OBJECT rsvpSenderAdspecHopCount MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderAdspecPathBw MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderAdspecMinLatency MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderAdspecMtu MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderAdspecGuaranteedSvc MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedBreak MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedCtot MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedDtot MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not
support Guaranteed Service."
OBJECT rsvpSenderAdspecGuaranteedCsum MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedDsum MIN-ACCESS read-only DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedHopCount MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedPathBw MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedMinLatency MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecGuaranteedMtu MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Guaranteed Service." OBJECT rsvpSenderAdspecCtrlLoadSvc MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Controlled Load." OBJECT rsvpSenderAdspecCtrlLoadBreak MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not
support Controlled Load."
OBJECT rsvpSenderAdspecCtrlLoadHopCount MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Controlled Load." OBJECT rsvpSenderAdspecCtrlLoadPathBw MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Controlled Load." OBJECT rsvpSenderAdspecCtrlLoadMinLatency MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Controlled Load." OBJECT rsvpSenderAdspecCtrlLoadMtu MIN-ACCESS not-accessible DESCRIPTION "This may be not-accessible if the system does not support Controlled Load." OBJECT rsvpSenderStatus MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpSenderFlowId MIN-ACCESS not-accessible DESCRIPTION "This object is needed only in a system that imple- ments IPv6." OBJECT rsvpResvType MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvDestAddr MIN-ACCESS read-only DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT rsvpResvSenderAddr MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvDestAddrLength MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvSenderAddrLength MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvProtocol MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvDestPort MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvPort MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvHopAddr MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvHopLih MIN-ACCESS read-only DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT rsvpResvInterface MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvService MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvTSpecRate MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvTSpecPeakRate MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvTSpecBurst MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvTSpecMinTU MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvTSpecMaxTU MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvRSpecRate MIN-ACCESS read-only DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT rsvpResvRSpecSlack MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvInterval MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvScope MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvShared MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvExplicit MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvRSVPHop MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvPolicy MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvStatus MIN-ACCESS read-only DESCRIPTION
"read-create access is not required. This may be
read-only."
OBJECT rsvpResvFlowId MIN-ACCESS not-accessible DESCRIPTION "This object is needed only in a system that imple- ments IPv6." OBJECT rsvpResvFwdStatus MIN-ACCESS read-only DESCRIPTION "read-create access is not required. This may be read-only." OBJECT rsvpResvFwdFlowId MIN-ACCESS not-accessible DESCRIPTION "This object is needed only in a system that imple- ments IPv6." ::= { rsvpCompliances 1 }
rsvpSessionGroup OBJECT-GROUP
OBJECTS {
rsvpSessionType, rsvpSessionDestAddr,
rsvpSessionDestAddrLength, rsvpSessionProtocol,
rsvpSessionPort, rsvpSessionSenders, rsvpSessionReceivers,
rsvpSessionRequests
}
STATUS current
DESCRIPTION
"These objects are required for RSVP Systems."
::= { rsvpGroups 1 }
rsvpSenderGroup OBJECT-GROUP
OBJECTS {
rsvpSenderType, rsvpSenderDestAddr, rsvpSenderAddr,
rsvpSenderDestAddrLength, rsvpSenderAddrLength,
rsvpSenderProtocol, rsvpSenderDestPort, rsvpSenderPort,
rsvpSenderHopAddr, rsvpSenderHopLih, rsvpSenderInterface,
rsvpSenderTSpecRate, rsvpSenderTSpecPeakRate,
rsvpSenderTSpecBurst, rsvpSenderTSpecMinTU,
rsvpSenderTSpecMaxTU, rsvpSenderInterval,
rsvpSenderLastChange, rsvpSenderStatus,
rsvpSenderRSVPHop, rsvpSenderPolicy,
rsvpSenderAdspecBreak, rsvpSenderAdspecHopCount,
rsvpSenderAdspecPathBw, rsvpSenderAdspecMinLatency,
rsvpSenderAdspecMtu, rsvpSenderAdspecGuaranteedSvc,
rsvpSenderAdspecGuaranteedBreak,
rsvpSenderAdspecGuaranteedCtot,
rsvpSenderAdspecGuaranteedDtot,
rsvpSenderAdspecGuaranteedCsum,
rsvpSenderAdspecGuaranteedDsum,
rsvpSenderAdspecGuaranteedHopCount,
rsvpSenderAdspecGuaranteedPathBw,
rsvpSenderAdspecGuaranteedMinLatency,
rsvpSenderAdspecGuaranteedMtu, rsvpSenderAdspecCtrlLoadSvc,
rsvpSenderAdspecCtrlLoadBreak,
rsvpSenderAdspecCtrlLoadHopCount,
rsvpSenderAdspecCtrlLoadPathBw,
rsvpSenderAdspecCtrlLoadMinLatency,
rsvpSenderAdspecCtrlLoadMtu, rsvpSenderNewIndex
}
STATUS current
DESCRIPTION
"These objects are required for RSVP Systems."
::= { rsvpGroups 2 }
rsvpResvGroup OBJECT-GROUP
OBJECTS {
rsvpResvType, rsvpResvDestAddr, rsvpResvSenderAddr,
rsvpResvDestAddrLength, rsvpResvSenderAddrLength,
rsvpResvProtocol, rsvpResvDestPort, rsvpResvPort,
rsvpResvHopAddr, rsvpResvHopLih, rsvpResvInterface,
rsvpResvService, rsvpResvTSpecRate, rsvpResvTSpecBurst,
rsvpResvTSpecPeakRate, rsvpResvTSpecMinTU,
rsvpResvTSpecMaxTU, rsvpResvRSpecRate,
rsvpResvRSpecSlack, rsvpResvInterval,
rsvpResvScope, rsvpResvShared, rsvpResvExplicit,
rsvpResvRSVPHop, rsvpResvLastChange, rsvpResvPolicy,
rsvpResvStatus, rsvpResvNewIndex
}
STATUS current
DESCRIPTION
"These objects are required for RSVP Systems."
::= { rsvpGroups 3 }
rsvpResvFwdGroup OBJECT-GROUP
OBJECTS {
rsvpResvFwdType, rsvpResvFwdDestAddr, rsvpResvFwdSenderAddr,
rsvpResvFwdDestAddrLength, rsvpResvFwdSenderAddrLength,
rsvpResvFwdProtocol, rsvpResvFwdDestPort, rsvpResvFwdPort,
rsvpResvFwdHopAddr, rsvpResvFwdHopLih, rsvpResvFwdInterface,
rsvpResvFwdNewIndex, rsvpResvFwdService,
rsvpResvFwdTSpecPeakRate, rsvpResvFwdTSpecMinTU,
rsvpResvFwdTSpecMaxTU, rsvpResvFwdTSpecRate,
rsvpResvFwdTSpecBurst, rsvpResvFwdRSpecRate,
rsvpResvFwdRSpecSlack, rsvpResvFwdInterval,
rsvpResvFwdScope, rsvpResvFwdShared, rsvpResvFwdExplicit,
rsvpResvFwdRSVPHop, rsvpResvFwdLastChange,
rsvpResvFwdPolicy, rsvpResvFwdStatus
}
STATUS current
DESCRIPTION
"These objects are optional, used for some RSVP
Systems."
::= { rsvpGroups 4 }
rsvpIfGroup OBJECT-GROUP
OBJECTS {
rsvpIfUdpNbrs, rsvpIfIpNbrs, rsvpIfNbrs, rsvpIfEnabled,
rsvpIfUdpRequired, rsvpIfRefreshBlockadeMultiple,
rsvpIfRefreshMultiple, rsvpIfRefreshInterval, rsvpIfTTL,
rsvpIfRouteDelay, rsvpIfStatus
}
STATUS current
DESCRIPTION
"These objects are required for RSVP Systems."
::= { rsvpGroups 6 }
rsvpNbrGroup OBJECT-GROUP
OBJECTS {
rsvpNbrProtocol, rsvpNbrStatus
}
STATUS current
DESCRIPTION
"These objects are required for RSVP Systems."
::= { rsvpGroups 7 }
rsvpNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { newFlow, lostFlow }
STATUS current
DESCRIPTION
"This notification is required for Systems sup-
porting the RSVP Policy Module using an SNMP
interface to the Policy Manager."
::= { rsvpGroups 8 }
The use of an SNMP SET results in an RSVP or Integrated Services reservation under rules that are different compared to if the reservation was negotiated using RSVP. However, no other security considerations exist other than those imposed by SNMP itself.
Fred Baker
Postal: Cisco Systems
519 Lado Drive
Santa Barbara, California 93111
Phone: +1 805 681 0115
EMail: fred@cisco.com
John Krawczyk
Postal: ArrowPoint Communications
235 Littleton Road
Westford, Massachusetts 01886
Phone: +1 508 692 5875
EMail: jjk@tiac.net
Arun Sastry
Postal: Cisco Systems
210 W. Tasman Drive
San Jose, California 95134
Phone: +1 408 526 7685
EMail: arun@cisco.com
This document was produced by the RSVP Working Group.
[1] Rose, M., Editor, "Management Information Base for
Network Management of TCP/IP-based internets", STD 17,
RFC 1213, May 1990.
[2] Information processing systems - Open Systems
Interconnection - Specification of Abstract Syntax
Notation One (ASN.1), International Organization for
Standardization. International Standard 8824, (December,
1987).
[3] Information processing systems - Open Systems
Interconnection - Specification of Basic Encoding Rules
for Abstract Notation One (ASN.1), International
Organization for Standardization. International Standard
8825, (December, 1987).